Machine Recycling Discussion and Moderated Newsgroup > Separate Parts
> Electrical Parts
> North
> New
> Honeywell micro switch limit switch LSC4L top plunger
Honeywell micro switch limit switch LSC4L top plunger
Honeywell Micro Switch Limit Switch LSC4L
The following is copied from the web:
* Operating Force (O.F.): 17,79 N max. [4 lb max.]
* Pretravel (P.T.): 1,78 mm max. [0.070 in max.]
* Overtravel (O.T.): 0.190 in min.
* Differential Travel (D.T.): 0,51 mm max. [0.020 in max.]
* Actuator: Top Plunger - Standard
* Circuitry: 2NC 2NO Double-Pole Double-Throw, Snap-Action, Double-Break
* Ampere Rating: 10 A (Thermal)
* Supply Voltage: 600 Vac and 250 Vdc max.
* Termination Type: 0.75 in - 14NPT conduit
* Housing Type: HDLS Non Plug-in
* Sealing: NEMA 1, 3, 4, 4X, 6, 6P, 12, 13
* Approvals: UL listed, CSA Certified, CE Certified, CCC Certified
* CSA File #: LR57326/Master Contract 152457
* Operating Temperature Range: -12 C to 93 C [10 F to 200 F]
* Agency Approvals and Standards: EN60947-1, EN60947-5-1
These switches include boss-and-socket head design for secure head-to-body retention, unique all-metal drive train for consistent operating characteristics even at high temperature (lasts longer without the need for frequent adjustment than drive trains with plastic parts,) self-lifting pressure plate terminals save wiring time, easily identified grounding terminal (inside) for compliance with OSHA and other regulatory agency standards, one piece flat gasket (seals better than gaskets that go around curves and corners, does not contact terminal pins to reduce chances of fluid migration,) front mounting and interchangeability of single- and double-pole switches, plug-in and non plug-in with one another and with other switch brands, tracking interchangeability of actuator levers for single- and double-pole switches, plug-in and non plug-in, twin shaft seals for an extra measure of protection, inner FC O-ring seal, outer Buna-N seal (all FC available,) FC shaft and diaphragm seals on side rotary switches, rugged corrosion-resistant zinc head and body are phosphate treated and epoxy finished, exclusive teller tab assures proper torque (when it cannot be moved the lever is tight enough to prevent slippage) and domestic and international conduit taps.