Machine Recycling Discussion and Moderated Newsgroup   >   Separate Parts   >   Electrical Parts   >   Datalogic balluff TL80-011 sensor/ contrast scanner

Datalogic balluff TL80-011 sensor/ contrast scanner


Here is some information from the manufacturer...
* Power supply: 10 ... 30 Vdc, reverse polarity protection
* Light emission: Red 630 nm / green 526 nm LED
* Spot dimension: 1.5 x 5 mm (9 mm lens)
* Operating distance: 7 ... 11 mm (9 mm lens)
* Operating distance with fibre-optics: 0 ... 5 mm proximity / 0 ... 15 mm through beam
* Depth of field: 2 mm (9 and 18 mm lenses)
* Setting: Multi-turn trimmer
* Indicators: Red OUTPUT LED red LEDs for trimmer rotation direction
* Output type: NPN or PNP, Rpull-down/up 10 k
* Saturation voltage: 1.2 V max. (NPN vers.) 2.2 V max. (PNP vers.)
* Output current: 200 mA max.; short-circuit protection
* Response time: 50 s (9, 18 mm, fibre-optic vers.)
* Switching frequency: 10 KHz max. (8, 18 mm, fibre-optic vers.) 3.3 KHz max. (28 mm vers.)
* Operating mode: Dark/light selectable
* Analog output range: 0 ... 5.5 Vdc (2 Vdc on white 90%) 2.2 k output resistance
* Timing function: 20 ms minimum output ON
* Connection: M12 4-pole conn., 3 m 5 mm cable or cable with Amphenol connector
* Electrical protection: Class 1
* Mechanical protection: IP67
* Fibre-optic material: Fibre in glass / sheath in metal fibre in PMMA / sheath in PE (OF-30)
* Operating temerature: -10 ... +55 C
* Storage temperature: -20 ... +70 C
* Fibre operating temperature: -30 ... +150 C (glass OF vers.) -30 ... +60 C (OF-30)
* Reference standard: EN 60947-5-2



Datalogic balluff TL80-011 sensor/ contrast scanner