New 12.1 multi-parameter patient monitor with printer
New 12.1 Multi-parameter patient Monitor 6-parameter
87998764.jpg picture by willimen
4564546.jpg picture by willimen
{ Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR.
{ 12.1" large-screen color TFT display
{ Built-in high-capacity battery, up to 4 hours working time
{ 7-lead ECG waveforms display, big fonts observational interface
{ Reviewable ECG waveforms, Maximum 240 hours reviewing graphic trends
{ Digital SpO2 technique, precise measurement for weak perfusion and finger shaking
{ Arrhythmia and S-T segment analysis and pacemaker detection
{ Protection against interference from defibrillation and electrosurgical Unit
{ Applicable to ICU, CCU, operation, adult, pediatrics and neonatal patient
{ Full lead: I, II, III, AVL, AVR, AVF and V
{ Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
{ Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
{ Band width: 0.05Hz-100Hz(3dB)
{ Heart rate: Scope: 15 times/minute to 300 times/minutes
{ Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
{ Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Analysis function should be started when using the above two kinds of function
{ Cuff gassing time less than 15 seconds
{ First-time gassing pressure: dynamic state 24kPa 180 mmHg
{ Manual selection: 9.3kPa 70 mmHg 13.3kPa 100 mmHg 16.0kPa 120 mmHg 18.6kPa 140 mmHg 20.0kPa 150 mmHg 21.3kPa 160 mmHg
{ Automatic detection period: 1 minute to 240 minutes
{ Stop size 1 min 1 min -10min , 5min(10 min -30min), 10min(30 min -90min) and 30min 90 min -240min
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure 2.7kPa 31.3kPa 20mmHg 235mmHg
{ Chest impedance method or concentration of carbon dioxide at end of respiration
{ Scope of chest impedance method 0 time/minute 100 minutes/minute
{ Precision of chest impedance method time/minute
{ Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg 0.4%vol-9.9%vol
{ Detection scope of respiration rate: 2 times/minute ->60 times/minute including baby
{ Detection precision of respiration rate: 1 time/minute
{ Type: Vascular/surface temperature
Invasive blood pressure (optional)
{ Type: direct and continuous detection
{ Scope: -6.67kPa(-50mmHg) 46.67kPa(350mmHg)
{ Precision: below 13.33kPa(100mmHg) 0.27kPa(2mmHg) 13.33k
{ Input resistance: not less than 500k
{ Sensitivity of sensor: 5 V/V/mmHg
{ Accuracy of sensor: 2 Isolation voltage: 4 kV
ECG, NIBP, SPO2, TEMP, RESP, Pulse Rate, Built-in rechargeable battery, Thermal printer
Optional: Dual TEMP, Single/Dual IBP, EtCO2