New brand 12.1 inch 6-parameter patient monitor+printer
2-7.jpg picture by risingmed001 1-8.jpg picture by risingmed001
New 12.1-inch display 6-parameter Patient Monitor + printer
Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR.
12.1" large-screen color TFT display
Built-in high-capacity battery, up to 4 hours working time
Reviewable ECG waveforms, Maximum 240 hours reviewing graphic trends
Digital SpO2 technique, precise measurement for weak perfusion and finger shaking
Arrhythmia and S-T segment analysis and pacemaker detection
Protection against interference from defibrillation and electrosurgical Unit
Applicable for ICU, CCU, operation, adult, pediatrics and neonatal patient
ECG, NIBP, SPO2, TEMP, RESP, PULSE, Built-in rechargeable battery
3-6.jpg picture by risingmed001 6-6.jpg picture by risingmed001 2-8.jpg picture by risingmed001
7-5.jpg picture by risingmed001 8-4.jpg picture by risingmed001 3-7.jpg picture by risingmed001
SPO2 sensor TEMP sensor disposable electrodes
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Scope: 15 times/minute to 300 times/minutes
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and
with 10 seconds kept for each time.
Analysis function should be started when using the above two kinds of function.
Cuff gassing time: less than 15 seconds
First-time gassing pressure: dynamic state 24kPa 180 mmHg)
Manual selection: 9.3kPa 70 mmHg), 13.3kPa 100 mmHg), 16.0kPa 120 mmHg)
18.6kPa(140 mmHg),20.0kPa 150 mmHg),21.3kPa(160 mmHg), Automatic detection period: 1 minute to 240 minutes
Stop size: 1 min 1 min -10min), 5min(10 min -30min), 10min(30 min -90min) and 30min 90 min -240min)
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure 2.7kPa 31.3kPa 20mmHg 235mmHg)
Chest impedance method or concentration of carbon dioxide at end o
Scope of chest impedance method 0 time/minute 100 minutes/minute
Precision of chest impedance method time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute including baby)
Detection precision of respiration rate: 1 time/minute
Type: Vascular/surface temperature
Invasive blood pressure (OPTIONAL)
Type: direct and continuous detection
Scope: -6.67kPa(-50mmHg) 46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) 0.27kPa(2mmHg) 13.33k
Input resistance: not less than 500k
Sensitivity of sensor: 5 V/V/mmHg
Accuracy of sensor: 2 Isolation voltage: 4 kV
Dual TEMP, Single/Dual IBP, EtCO2