Machine Recycling Discussion and Moderated Newsgroup   >   Full Machines   >   Complete Machines   >   Agricultural   >   West   >   New   >   New fluke 435 basic power quality analyzer * * msrp 6835

New fluke 435 basic power quality analyzer * * msrp 6835


Fluke 435 BasicPower Quality Analyzer
* POWER QUALITY ANALYZER 3 PHASE, W/O CURRENT PROBES
* Hard carrying case with rollers
* Printed getting started manual
If needed we can Calibrate for an additional $149.99 a $299.99 service
The World s Leading 3-Phase Power Quality Troubleshooter Expands its Capabilities.
Introducing the Class A Fluke 435 with enhanced logging and reporting.
The Fluke 434 and 435 three-phase power quality analyzers help you locate, predict, prevent and troubleshoot problems in three and single phase power distribution systems. Troubleshooting is faster with on-screen display of trends and captured events, even while background recording continues. The new IEC standards for flicker, harmonics and power quality are built right in to take the guess work out of power quality
* Fully Class A Compliant with 0.1% voltage accuracy, test according to the stringent international IEC 61000-4-30 Class A standard
* Logger function - Configure for any test condition with memory up to 400 parameters at user defined intervals
* New Fluke Power Log software Easily view logged data and generate reports
* Flexible current probes included these new 3000A CAT IV flexis are instrument powered (no more batteries)
* Double the memory for expanded logging time
Fluke 434 and 435 Enhancements
* Expanded voltage configurations with 2 and 2.5 element modes
* Supports GPS time synchronization according to IEC61000-4-30 via optional GPS430 module
* Phase angle resolution improved to 0.1 resolution and referenced to L1/A voltage
* Phase rotation indicator provides clear indication of the phase rotation direction to determine correct connections.
* Hz resolution improved to 0.001Hz
* Rapid voltage change measurement now also shows the absolute voltage change to characterize the effects of load switching.
The Fluke 434 and 435 three-phase power quality analyzers help you locate, predict, prevent and troubleshoot problems in three and single phase power distribution systems. Troubleshooting is faster with on-screen display of trends and captured events, even while background recording continues. The new IEC standards for flicker, harmonics and power quality are built right in to take the guess work out of power quality.
* CAT IV flexible current probes with no battery required
* Long-term logging capability
* Easy-to-use reporting and analysis software
* Flexibility to record up to 400 parameters simultaneously
* Troubleshoot real-time: Analyze the trends using the cursors and zoom tools even while background recording continues
* Highest safety rating in the industry 600V Cat IV / 1000V CAT III
* Automatic transient mode captures 200kHz waveform data on all phases simultaneously up to 6kV
* Measure all three phases and neutral with included 4 current probes
* AutoTrend: every measurement you see is always automatically recorded, without any setup
* System-Monitor: Up to seven power quality parameters on one screen according to EN50160
* Inrush mode for troubleshooting nuisance circuit breaker tripping
* Rugged, handheld troubleshooter with Fluke 3 year warranty
* Seven hours operating time per charge on NiMH battery pack
* View graphs and generate reports with included analysis software
CAT IV 600 V and CAT III 1000 V safety rating:
Designed to help protect you and your equipment, the Fluke 430 Series analyzers and accessories are all certified to meet the stringent standards for use in CAT IV 600 V and CAT III 1000 V environments. They are the first tools of their kind to carry the CAT IV rating for use in power connections and outlets throughout a low-voltage power distribution system.
AutoTrend feature provides fast insight into changes over time. Every displayed reading is automatically recorded without having to set thresholds or intervals. Analyze the trends using the cursors and zoom tools even while background recording continues.
AutoTrend automatically records all displayed parameters in the background. Toggle between data and trend view, and use cursors and zoom to analyze measurements without interrupting the recording.
The Fluke 435 is fully compliant with the new IEC 61000-4-30 Class-A standard. With this powerful capability, all measurements will be consistent and reliable in accordance with the latest international standard.
Power quality measurement is a relatively new, and quickly evolving field. There are hundreds of manufacturers around the world with unique measurement methodologies. Whereas basic single- and three-phase electrical measurements like rms voltage and current were defined long ago, many power quality parameters were not previously defined, forcing manufacturers to develop their own algorithms. With so much variation between instruments, electricians tend to waste too much time trying to understand an instrument s capabilities and measurement algorithms instead of understanding the quality of the power itself!
The new IEC 61000-4-30 Class-A standard takes the guesswork out of selecting a power quality instrument. The standard IEC 61000-4-30 defines the measurement methods for each parameter to obtain reliable, repeatable and comparable results. In addition, the accuracy, bandwidth and minimum set of parameters are all clearly defined.
Measure true-rms and peak voltage and current, frequency, dips and swells, transients, interruptions, power and power consumption, peak demand, harmonics up to the 50th, interharmonics, flicker, mains signaling, inrush and unbalance.
Logger: record the detail you need
User-configurable, long-term recording of MIN, MAX and AVG readings for up to 100 parameters on all 4 phases. Enough memory is available to record 400 parameters for up to a month with 10 minute resolution, or capture smaller variations with resolution down to 0.5 seconds.
Simple menu structure with logical function grouping gives fast access to key measurements.
Inrush function automatically triggers off of current, and captures start up measurements on motors and other devices to help determine trip levels.
Every time an event or voltage distortion is detected, the instrument triggers and automatically stores voltage and current waveforms on all three phases and neutral. The analyzer will also trigger when a certain current level is exceeded. Up to 40 dips, swells, interruptions and transients can be captured this way. You can see voltage transients as high as 6 kV and as fast as 5 microseconds.
A detailed list is given of all events falling outside the set limits. By scrolling through the events list and selecting an event, the event can be analyzed in detail.
System-Monitor: Summary screen of overall power quality health
A single push of the MONITOR button delivers a dashboard display of rms voltage, harmonics, flicker, interruptions, rapid voltage changes, swells, unbalance, frequency and mains signaling. The dashboard is updated live, showing compliance of each parameter to EN50160 limits or your own limits. Color-coded bars clearly show which parameters are inside (pass) or outside limits (fail). During a monitor session, you can easily drill down to more detail of any parameter to view and capture its trend for a report.
The System-Monitor overview screen gives instant insight into whether the voltage, harmonics, flicker, frequency and the number of dips and swells fall outside the set limits.
Extensive data analysis possibilities
The Fluke 430 Series provides three ways to analyze measurements. Cursors and zoom tools can be used live while taking measurements, or off line on stored measurement data. Additionally, the stored measurements can be transferred to a PC with the included software to perform custom analysis and create reports. Measurement data can also be exported to common spreadsheet programs. Store up to 10 measurement datasets and up to 50 screen captures for use in reports.
Perform custom analysis and create reports with included software. Measurement data can also be exported to common spreadsheet programs.
Scope view shows voltage and current waveforms for three phase installations. You can toggle to a phasor diagram at any time.
Phasor diagram shows voltage and current unbalance, and helps verify connections.
The full color display uses region specific industry standard color-coding (user selectable) to correlate measurements with actual wiring.
Generate reports and view graphs with Fluke Power Log Software
Designed to quickly view recorded data, the included Power Log software displays all recorded parameters on interactive trends. Generate a professional report with the Report Writer function, or copy and paste images into report document manually.
View recorded data in simple graphs and tables.
Easily customize the report by selecting time period and measurements to include.
Create professional reports quickly and easily.
quickly diagnose problems on-screen to get your operation back online
detect and prevent power quality issues before they cause downtime
* Quality of Service Compliance
validate incoming power quality at the service entrance
uncover hard-to-find or intermittent issues
verify electrical system capacity before adding loads
quantify energy consumption before and after improvements to justify energy saving devices
Measures voltage, current, dips, swells, interruptions, harmonics, inter-harmonics, flicker, power, energy, transients, frequency, unbalance, inrush, EN50160 overview
Logger function with multi-parameter logging
water-tight hard case with rollers
Report generation and logger analysis software Power Log
* Optional functionality can be added with upgrade kit
** Requires optional Accessory
Number: 4 voltage and current (3 phases + neutral)
Maximum voltage: 1000 Vrms (6 kV peak)
Maximum sampling speed: 200 kS/s on each channel simultaneously
Measurement range: 1 ... 1000 V
Measurement range: 1 ... 1400 V
Measurement range: 1.0 ... > 2.8
Measurement range: 0 ... 20 kA
Measurement range: 0 ... 5.5 kA
Measurement range: 42.50 ... 57.50 Hz
Measurement range: 0.0% 100% of Vnom
Accuracy: 0.2% of nominal voltage
Measurement range: 0 ... 20 kA ?
Measurement range: DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7
Measurement range: 0.0 1000 V
Accuracy: 0.05% of nominal voltage
Measurement range: 0.0 4000 mV x clamp scaling
Measurement range: Depends on clamp scaling and voltage
Accuracy: 5% n x 2% or reading, 10 counts
Measurement range: 0.0 100.0%
Accuracy: 2.5% V and A ( 5% Watt)
Measurement range: 0 3500 Hz
Measurement range: -360 ... +360
Measurement range: 1.0 20.00 MVA
Measurement range: 00.00 200.0 GVAh
Measurement range: 0.00 20.00
Minimum detect duration 5 s (200kS/s sampling)
Measurement range: 0.000 20.00 kA
Accuracy: 1% of meas 5 counts
Measurement range: 7.5 s ... 30 min
Accuracy: 20 ms (Fnom = 50 Hz)
Sampling: 5 readings/sec continuous sampling per channel
Memory: 1800 min, max and avg points for each reading
Recording time: Up to 450 days
Zoom: Up to 12x horizontal zoom
Screens & data: 50, shared memory divided between logging, screens and data sets
Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle
The advanced functions Interharmonics, Energy, Transients and Inrush are optional for the Fluke 434 and standard available on the Fluke 435.
EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV ANSI/ISA S82.01
Rechargeable NiMH pack (installed): >7 hours
Battery charging time: 4 hours typical
Vibration: 3 g according to MIL-PRF-28800F Class 2
Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof)



New fluke 435 basic power quality analyzer * * msrp 6835