New fluke 1735 three-phase power logger * * msrp 2935 usd


Fluke 1735 Three Phase Power Logger
Power quality logging, electrical load studies and energy consumption testing.
The Fluke 1735 Power Logger is the ideal electrician or technician s power meter for conducting energy studies and basic power quality logging. Set the Power Logger up in seconds with the included flexible current probes and color display. The power quality meter measures most electrical power parameters, harmonics, and captures voltage events.
* Load studies - verify electrical system capacity before adding loads
* Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices
* Harmonics measurements - uncover harmonic issues that can damage or disrupt critical equipment
* Voltage event capture - monitor for dips and swells that cause spurious resets or nuisance circuit breaker tripping
Introducing a Simple 3-Phase Power Logger from the Leader in Power Quality.
The Fluke 1735 Power Logger is the ideal electrician or technician s tool for conducting energy studies and basic power quality logging. Set the 1735 up in seconds with the included flexible current probes and color display. The 1735 logs most electrical power parameters, harmonics and captures voltage events.
* Color display for easy setup and verification
* Four included triple range flexible current probes with no battery required
* Easy-to-use analysis and reporting software
* Affordable price point for simple 3-phase power quality measurements
* Record power and associated parameters for up to 45 days
* Monitor maximum power demand over user-defined averaging periods
* Prove the benefit of efficiency improvements with energy consumption tests
* Measure harmonic distortion caused by electronic loads
* Improve reliability by capturing voltage dips and swells from load switching
* Easily confirm instrument setup with color display of waveforms and trends
* Measure all three phases and neutral with included 4 flexible current probes
* View graphs and generate reports with included Power Log software
* Compact, rugged design with IP65 case, 600 V CAT III and 2-year warranty
* View graphs and generate reports with included analysis software
Electrical load studies, energy consumption testing, and eneral power quality logging
The Fluke 1735 Three-Phase Power Logger is the ideal electrician or technician s tool for conducting energy studies and basic power quality logging. Set up the 1735 in seconds, with the included flexible current probes and color display. The 1735 logs most electrical power parameters, harmonics and captures voltage events.
Log the most common parameters
Designed to measure the most critical three-phase power parameters, the 1735 can log rms voltage, rms current, phase angle, voltage events, voltage and current THD, voltage and current harmonics up to the 50th, active power, reactive power, power factor, active energy, reactive energy, and more. With memory for up to 45 days of data, the 1735 can uncover intermittent or hard-to-find issues.
Conduct load studies for up to 45 days and view saved data on-screen or on a computer.
Quantify energy consumption quickly on-screen or log to memory for extended periods.
Assess voltage and current harmonics up to the 50th.
View waveforms onscreen to uncover waveform distortion and to verify correct voltage and current connections.
Generate reports and view graphs with Fluke Power Log Software
Designed to quickly view recorded data, the included Power Log software displays all recorded parameters on interactive trends. Generate a professional report with the Report Writer function, or copy and paste images into report document manually.
View recorded data in simple graphs and tables.
Easily customize the report.
Create professional reports.
verify electrical system capacity before adding loads
quantify energy consumption before and after improvements to justify energy saving devices
uncover harmonic issues that can damage or disrupt critical equipment
monitor for dips and swells that cause spurious resets or nuisance circuit breaker tripping
Display: VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
Quality: Developed, designed and manufactured according to DIN ISO 9001
Memory: 4 MB Flash memory, 3.5 MB for measuring data
Interface: RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
Line frequency: 50 Hz or 60 Hz, user-selectable, with automatic synchronization
Power supply: NiMH battery-pack, with ac adapter (15 V to 20 V/0.8 A)
Operation time with battery: Typical > 12 hours without backlight and > 6 hours with backlight high
Dimensions: 240 mm x 180 mm x 110 mm
Weight: 1.7 kg, including battery
Working temperature range: -10 C to +50 C
Storage temperature range: -20 C to +60 C
Operating temperature range: 0 C to +40 C
Reference temperature range: 23 C 2 C
Temperature coefficient: 0.1 % of the measured value per C from the reference
Intrinsic error: Refers to reference temperature, maximum deviation is guaranteed for two years
Operating error: Refers to operating temperature range, maximum deviation is guaranteed for two years
Climatic class: C1 (IEC 654-1) -5 C to +45 C, 5% to 95% RH, no dew
Housing: Cycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
Emission: IEC/EN 61326-1:1997 class B
Immunity: IEC/EN 61326-1:1997
Safety: IEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
Protection: IP65; EN60529 (refers only to the main housing without the battery compartment)
RMS values are measured with a 20 ms resolution.
Measuring range: 57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V ac
Intrinsic error: (0.2% of measured value + 5 digits)
Operating error: (0.5% of m. v. + 10 digit)
Measuring range: 100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/690 V/720 V/830 V ac
Intrinsic error: (0.2% of m. v. + 5 digit)
Operating error: (0.5 % of m. v. + 10 digit)
Flexi set I ranges: 15 A/150 A/3000 A rms (at sine)
Current clamp ranges: 1 A/10 A
Ranges 150 A/3000 A and 1 A/10 A
Intrinsic error: (0.5 % of m. v. + 10 digit)
Operating error: (1 % of m. v. + 10 digit)
Intrinsic error: (0.5 % of m. v. + 20 digit)
Operating error: (1 % of m. v. + 20 digit)
The errors of the current probes are not considered.
Flexi Set measuring error: (2% of m. v. + 10 digit)
Position influence: (3 % of m. v. + 10 digit)
Note: When using Flexi Set please make sure to position the conductor opposite to the Flexi Set-lock
Power measurement (P - Active, S - Apparent, Q- reactive, D - Distorting
Measuring range: see V rms and A rms measurement
Power errors are calculated by adding the errors of voltage and current
Additional error due to power factor PF
Maximum range with voltage range 830 V delta-connection and 3000 A current range is 2.490 MW, higher displayed values possible when using PTs and CTs with ratio feature
Intrinsic error: (0.7 % of m.v. +15 digit)
Operating error: (1.5 % of m.v. + 20 digit)
Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW.
The errors of the current sensors themselves have not been considered.
Energy measurement (kWh, KVAh, kVARh)
Intrinsic error: (0.7 % of m.v.+ F variation error* + 15 digit)
Operating error: (1.5 % of m.v. + F variation error* + 20 digit)
Accuracy: 1 % of full scale
Measuring range: 46 Hz to 54 Hz and 56 Hz to 64 Hz
Intrinsic error: (0.2 % of m. v. + 5 digit)
Operating error: (0.5 % of m. v.+ 10 digit)
Measuring range: To 50th harmonic (< 50 % of nom)
Vm, Im, THDV, THDI: IEC 61000-4-7:2002, Class II
THDV: for THD < 3% 0.15% at Vnom
THDI: for THD < 10% 0.5% at Inom
Vm and Im are measured values of harmonic m
Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms.
Intrinsic error: (1% of m.v. + 10 digit)
Operating error: (2% of m.v. + 10 digit)



New fluke 1735 three-phase power logger * * msrp 2935 usd